MEG Analysis: Fast, accurate analysis of water, oil, gas, and control fluids

0 Reviews
0 Followers
9 Deploys

OMMICA is a low-cost alternative to GC for ethylene glycol detection in multiple fluids and phases. It may also be used to manage MEG regeneration systems,

Page last modified
February 22 2024

The OMMICA MEG analysis consists of a simple, highly accurate, portable colourimetric test to determine ethylene glycol in oil and water. It may be used in all types of crude oil, and in oil-based control fluids. It may also be used in water at all concentrations of MEG, for example to manage MEG regeneration processes. 

Accuracy is gained by addition of accurately measured reagents to a sample. This is then reacted at a specific time and temperature, to control the reaction and the resultant colour gives the level of MEG.

Absorbance of the reacted sample colour is measured using a colourimeter to give an accuracy of +/- 1ppm.

The analysis has been developed to be as accurate as gas chromatography, but allow on-site testing to take place in the field or offshore, through use of portable equipment.

Pros & Limitations
1
Significant cost savings on traditional analysis methods
1
Designed to be easy for non-specialist users to use well
1
As accurate as Gas Chromatography
1
Designed to be used on- and off- shore
1
Water extraction of oil not required before analysis of oil samples
0
OMMICA is not an ASTM method, however it correlates well with the standard ASTM method using GC
0
Additional sample processing (dilution) required for MEG regeneration systems management (instructions provided)
0
The OMMICA method may require a couple of hours training for optimum results (can be provided)
Specification
Specification Title Specification Description
Areas of application
Pipelines, MEG regeneration systems, oil-based control fluids, airport water runoff monitoring
Accuracy
+/- 2 ppm
Detection threshold
< 1 ppm in oil and water, < 10 ppm in gas
Range (standard)
1 to 500 ppm (oil), 2 to 100 ppm (water)
Range (extended)
Up to 10% (oil), up to 80% (water)
Quality
3rd party testing confirms equivalence with ASTM method (GC) (Major analytical contractor)
Efficiency
Up to 100 samples/day possible
Cost reduction
Low set-up cost compared with GC. Low ongoing OPEX
Operational impact
No need to wait for samples to be helicoptered back onshore to a lab, and for a third party to analyse samples, before decisions can be made
Deployment
Can be effectively used by non-specialists
Training
Dedicated YouTube training videos channel, summary videos on website, in-person training can be provided if required
Versatility
Suitable for use on or offshore. Only requires 1 m2 (or less) of working space. Robust equipment

Reviews

Get access to reviews

to your explorer or platform subscription to get access to the reviews written about this technology.

Technology Readiness Level

The Technology Readiness Level (TRL) indicates the maturity level of novel technologies. Learn more about the TRL scale used by us.

[9/9]

Development Technology demonstration Mature / Proven
Ask the supplier
 to contact this technology supplier.

OMMICA Ltd develop and manufacture novel chemical testing technology to help clients save on refinery penalties, using cost effective technology, which allows management of fluids prior to custody transfer.

Relative Business Impact

Solution Deployed By
Company Name

to your explorer or higher plan to get access to all the 9 deployment references.

Last Deployment YearTotal DeploymentsComment