2
Likes
The storage of hydrocarbon or chemical liquids in above-ground storage tanks is an important element in the energy supply chain. A major concern for the integrity of a storage tank is the condition of the tank bottom. Whereby corrosion is one of the most common threats.
Through sensitive detection and diagnosis, our TBIT Ultra service is capable of accurately sizing the smallest metal loss defects, such as pinholes or microbiologically induced corrosion, helping to optimize your storage tank inspection program.
Specification Title | Specification Description |
---|---|
Detection Threshold
|
0.1t Ø2mm [0.08”] x 0.2t
|
Sizing Accuracy Depth
|
±0.04t
|
Scan Speed
|
100 m2 /h or 328 ft2/h
|
Internal/External Discrimination
|
Yes
|
No. of Sensors
|
1029 (Hall + EC)
|
Plate Thickness
|
4-16mm [0.156”-0.625”]
|
Coating Thickness
|
Up to 6mm [ 0.236”] (automatic sizing) 6-10mm [0.236”-0.394”] (detection only)
|
The Technology Readiness Level (TRL) indicates the maturity level of novel technologies. Learn more about the TRL scale used by us.
[8/9]